Network-M2のファームウェア 1.6.6 が公開されました。
バージョンアップを実施すると、ネットワークカードは再起動しますが、UPS本体は出力を停止することなく稼働し続けます。
以下、Eaton発行のリリースノート(原文)
========================================================================================== Firmware release notes for Eaton Gigabit Network Card for UPS (Network-M2, P/N 744-A3983). Firmware : Release 1.6.6 Date : 2019/7/30 Eaton (c) 2019 ========================================================================================== Upgrade/Compatibility: This section describes the considerations for upgrading from a previous release. See the Gigabit Network card 1.6.6 Firmware Upgrade Notice document for more detailed instructions. 1.6.6 is compatible with all Eaton Gigabit Network cards. Earlier versions can be upgraded to 1.6.6 according to the procedure described in the manual without special considerations. Downgrade to earlier versions is possible but not recommended. =============================== Release 1.6.6 July 2019 =============================== Software compatibility: IPP 1.61 and higher, IPM 1.61 and higher Supported UPS: Eaton 5P, 5PX, 5SC Rack, 9PX, 9PXM, 9SX, 9E, 93PM (fw 1.48 ->), 93PS (fw 2.50 ->), 91PS Improvements: - NOTE: Changed DIP switch 3 function from admin password reset to sanitization (full reset and data purge) - Sanitization improvements (Done at boot after command, major version downgrade or dip switch 3 change) - Added support for RADIUS authentication - Added support for Syslog integration - Added support for Li-Ion batteries - Added 'Operator' profile - Measurement values option on the synoptic view - XUPS MIB enhancements - Added email/ping6/traceroute6/whoami options in CLI - Save and restore with passphrase and with fields including encrypted password - Eaton sensor new MIB - Battery page information in Meters - Added STARTTLS to SMTP (email) Fixes: - Issue with Chrome and self signed certificate - Issue with upgrading after changing admin username - Cybersecurity updates - Don't allow port 80 for https - Issue with card unable to handle a hostname with a number as the first character - Web server performance issue with RNDIS - IPV6 support on SNMP, LDAP, NTP - SNMP bug fixes: - Manage the trap UpsShutdownPending and also the related alarm in the Eaton Xups Mib. - Manage a trap entry related to the alarm UpsAlarmShutdownPending in the IETF MIB. - Manage the oid xupsBatteryLastReplaceDate in the Eaton Xups Mib. - Oid upsConfigDateAndTime cannot be written. - Implement the data xupsBatteryLastReplaceDate in the mib Eaton Xups. - Suppress final 0 in Mib data oid that are part of table in the Mibs. - Trap binded variables oid are completed either with 0 for scalar data, or with the index for table data. - Eaton Xups Mib data named "---AverageCurrent" renamed to "---TotalCurrent" in the description Mib file to be consistent with the UPS measures. Known issues and limitations: - If LDAP group name contains a space login to the card will become impossible. - Web UI cache needs to be cleared with CTRL+F5 after an upgrade - Up to 30 shutdown agents can be connected. - Environmental probe values cannot be set to trigger shutdown. =============================== Release 1.5.3 January 2019 =============================== Software compatibility: IPP 1.61 and higher, IPM 1.61 and higher Supported UPS: Eaton 5P, 5PX, 5SC Rack, 9PX, 9SX, 9E Fixes: - Increased LDAP username and password length to match LDAP maximum - Fixed IPv6 addressing issues with SNMPv3 and LDAP Known issues and limitations: - Web UI cache needs to be cleared with CTRL+F5 after an upgrade - Up to 30 shutdown agents can be connected. - Environmental probe values cannot be set to trigger shutdown. =============================== Release 1.5.1 December 2018 =============================== Software compatibility: IPP 1.61 and higher, IPM 1.61 and higher Supported UPS: Eaton 5P, 5PX, 5SC Rack, 9PX, 9SX, 9E Improvements: - Added support for LDAP authentication - Added measurements display on the synoptic view of the home screen - Added multiphase support on the synoptic view - Shutdown procedures disabled when no agents are connected - Alarms page reworked - XUPS MIB enhancements - Added tolerance to communication losses with UPS Fixes: - Cybersecurity updates - Communication and certificate issues with IPM and IPP software Known issues and limitations: - Web UI cache need to be cleared with CTRL+F5 after an upgrade - Up to 30 shutdown agents can be connected. - Environmental probe values cannot be set to trigger shutdown. - Length of username and groupname in LDAP are both limited to 31 characters --------------------------------------------------------------------------------
Network-M2 ファームウェアアップグレード手順
https://www.eaton-daitron.jp/techblog/8108.html