Network-M2のファームウェア 1.7.5 が公開されました。
重要:0~3kVAの9PXおよび9SXで使用する場合、1.7.5にアップグレードする事を強くお勧めします!
バージョンアップを実施すると、ネットワークカードは再起動しますが、UPS本体は出力を停止することなく稼働し続けます。
以下、Eaton発行のリリースノート(原文)
========================================================================================== Firmware release notes for Eaton Gigabit Network Card for UPS (Network-M2, P/N 744-A3983) and Eaton Industrial Gateway Card (INDGW-M2, P/N 744-07774) Firmware : Release 1.7.5 Date : 2019/11/18 Eaton (c) 2019 ========================================================================================== NOTE: It is highly recommended to upgrade all cards that are used with 0-3 kVA 9PX and 9SX to 1.7.5! Upgrade/Compatibility: This section describes the considerations for upgrading from a previous release. See the Gigabit Network card 1.7.5 Firmware Upgrade Notice document for more detailed instructions. 1.7.5 is compatible with all Eaton Gigabit Network and Industrial Gateway cards. Notice that there are separate upgrade packages for each card type. Earlier versions can be upgraded to 1.7.5 according to the procedure described in the manual without special considerations. Downgrade to earlier versions is possible but not recommended. =============================== Release 1.7.5 November 2019 =============================== Software compatibility: IPP 1.61 and higher, IPM 1.61 and higher Supported UPS: Eaton 5P, 5PX, 5SC Rack, 9PX, 9PXM, 9SX, 9E, 93PM (fw 1.48 ->), 93PS (fw 2.50 ->), 91PS, 93E 15-80 EMEA (fw 8.00.01 ->), 93E G2 EMEA (fw 4.0.20->) Fixes: - Fixed communication issue with 9PX 0 - 3 kVA and 9SX 0 - 3 kVA UPS which could lead to UPS becoming unresponsive or dropping the load. =============================== Release 1.7.4 October 2019 =============================== Software compatibility: IPP 1.61 and higher, IPM 1.61 and higher Supported UPS: Eaton 5P, 5PX, 5SC Rack, 9PX, 9PXM, 9SX, 9E, 93PM (fw 1.48 ->), 93PS (fw 2.50 ->), 91PS, 93E 15-80 EMEA (fw 8.00.01 ->), 93E G2 EMEA (fw 4.0.20->) Improvements: - Ability to work with IPM 1.67 to shut down VxRail systems. - Ability to create certificates with user defined Country, State or Province, City or Locality, Organization name and unit, Contact email address - Sensor log download and email capability - Improvements in configuration save and restore, support for IPM 2.0.1 mass configuration feature - Monitoring of card resources to help in troubleshooting. Fixes: - If LDAP group name contains a space login to the card will become impossible. - SNMP: Battery alarms, Battery last replacement date, sensor index, negative offset for temperature and humidity - Battery status unknown on the synoptic with 9E 3K - Invalid Recommended replacement date for battery - Temperature compensated charging with 93PM, 93PS, 91PS, 93E - System logs blocking when syslog is enabled without server active configuration - Modbus registers "Nominal VA" and "Nominal kW" on Industrial Gatway Card (INDGW-M2) Known issues and limitations: - LDAP remote groupname entered in profile mapping settings must be composed only of alphanumerics, underscore and hyphen characters - User defined certificate fields State・Organization・Organization unit・must be composed of alphanumerics, space or following characters ・=()・ - Web UI cache needs to be cleared with CTRL+F5 after an upgrade - Up to 30 shutdown agents can be connected. - Environmental probe values cannot be set to trigger shutdown. - Environmental probe settings cannot be saved or restored
Network-M2 ファームウェアアップグレード手順
https://www.eaton-daitron.jp/techblog/8108.html